View Full-Size Image |
Call for Pricing
(Excluding VAT @ 17.5%)
|
PDF Download:
Datasheet
GasAlertMicro 5 IR portable gas detector simultaneously monitors up to five atmospheric hazards including carbon dioxide (CO2), oxygen (O2), combustible gas (% LEL), and a wide selection of individual electrochemical toxic sensors. Compact and lightweight, GasAlertMicro 5 IR activates audible, visual and vibrating alarms in the event of a low, high, TWA or STEL alarm condition.
Highly configurable to suit a range of applications, the GasAlertMicro 5 IR comes as a diffusion or pumped instrument with either alkaline or NiMH rechargeable hot-swappable battery pack and has optional datalogging capabilities. Standard features include confidence beep, automatic calibration, full function self-test and an extended selection of user-settable field options.
| Gas | Measuring Range |
Default Resolution |
High Resolution |
TWA* |
STEL* |
LOW* |
HIGH* |
| O2 | 0-30.0% |
0.50% |
N/A |
N/A |
N/A |
19.5 |
23.6 |
| H2S | 0-500 ppm |
1 ppm |
0.1 ppm |
10 |
15 |
10 |
15 |
| CO | 0-999 ppm |
1 ppm |
N/A |
35 |
50 |
35 |
200 |
| TwinTox (H2S) | 0-500 ppm |
1 ppm |
0.1 ppm |
10 |
15 |
10 |
15 |
| TwinTox (CO) | 0-500 ppm |
1 ppm |
N/A |
35 |
50 |
35 |
200 |
| PH3 | 0-5 ppm |
1 ppm |
0.1 ppm |
0.3 |
1.0 |
0.3 |
1.0 |
| SO2 | 0-150 ppm |
1 ppm |
0.1 ppm |
2 |
5 |
2 |
5 |
| NO2 | 0-99 ppm |
1 ppm |
0.1 ppm |
2.0 |
2.0 |
2.0 |
5.0 |
| HCN | 0.30 ppm |
1 ppm |
0.1 ppm |
4.7 |
10.0 |
4.7 |
10.0 |
| CI2 | 0-50 ppm |
1 ppm |
1 ppm |
0.5 |
1.0 |
0.5 |
1.0 |
| NH3 | 0.100 ppm |
1 ppm |
0.1 ppm |
25 |
35 |
25 |
50 |
| CIO2 | 0-1.0 ppm |
0.1 ppm |
0.01ppm |
0.1 |
0.3 |
0.1 |
0.3 |
| O3 | 0-1.0 ppm |
0.1 ppm |
0.01 ppm |
0.1 |
0.1 |
0.1 |
0.1 |
| IR-CO2 | 0-50,000 ppm 0-5.0% v/v |
50 ppm 0.1% |
N/A |
5,000 0.5% |
30,000 3.0% |
5,000 0.5% |
30,000 3.0% |
| Combustible Gases |
0-100% LEL 0-5.0% v/v |
1% |
N/A |
N/A |
N/A |
10% |
20% |
(* Note: alarm setpoints may vary by region)
Auto zero: Yes
Calibration: Automatic
Backlight: Low light (auto); alarm condition (auto); reactivation on demand
Sensor: Infrared CO2; plug-in, electrochemical cell (toxic and oxygen); catalytic (LEL)
User field options: Confidence beep, set STEL period, force calibration on start-up, enable / disable sensor, passcode protection, latching alarms, span level, passed calibration user-lockout option, “SAFE” display function, stealth mode, fast pump, oxygen auto-cal on start-up, alarm only backlight mode, combustible gas measurement (% LEL or % by volume methane), LCD language option, STEL calculation choice, TWA calculation choice, combustible correction factor options, CO2 measurement (ppm or %vol), user-settable calibration gas level, high resolution, clock
ALARM INDICATORS: Clearly advises alarm conditions with audible, visual and vibrator alarms
Visual alarms: Two flashing alarm bars visible from all angles, LCD indicates gas present and alarm levels encountered
Audible alarm: Typically 95 dB at 1 ft. / 30 cm variable pulsed
Vibrator alarm: Pulses warning in gas alarm conditions or for any status alarms
Status alarms: Low battery, over range, multiple gas, pump, failed sensor and missing sensor
ALARM LEVELS: Instantaneous Low Alarm for all gases; Instantaneous High Alarm for all gases; TWA (time-weighted average) and STEL (short-term exposure limit) for toxics/CO2
LCD: Continuous, alphanumeric gas readout and status display advises:
Peak (MAX)/STEL/TWA: Records exposures and displays on demand
Alarm setpoints: Displayed on activation and on demand
Calibration due date: Days remaining displayed on start-up
Clock: Real-time clock setting displayed on start-up
TESTS:
Full function self-test: Sensor integrity, circuitry, battery and audible/visual alarms on activation
Battery: Continuous
GENERAL SPECIFICATIONS: Rugged, composite material; two-shot molded polymer case with integral anti-shock boot
Operating temperature: -4 to 122oF / -20 to 50°C (-4 to 104°F / -20 to 40oC for NH3)
Humidity: 0 - 95% RH (non-condensing)
EMI/RFI: Complies with EMC Directive 89/336/EEC
Protection: Highly water resistant and dust proof housing
Battery Options: Up to 10 hours (typical) in diffusion mode with “hot-swappable” rechargeable or AA alkaline battery packs
Size: 5.7 x 2.9 x 1.5 in. / 14.5 x 7.4 x 3.8 cm
Weight: 13.1 oz. / 370 g
WARRANTY: Full 2-year warranty including sensors (1 year on NH3 sensor)
DATALOGGER OPTIONS: User-downloadable datalogger
Data recorder: All events and occurrences (calibration zero adjustment, calibration span adjustment, gas readings, TWA, STEL, alarm condition, failures detected by the microprocessor).
Sampling rate: Factory set at 5-second intervals and user-settable from 1 to 127-second intervals
Storage: 8 months of continuous data at 5 second intervals via memory card; when full, the wrap-around feature replaces oldest data with most recent data
| Lost Password? | |
| No account yet? Register | |
|
|
COSHH & Air Sampling
Cardiff - 23 September 2010
Environmental Noise
Reading - 21 October 2010
Noise and Vibration
Middlesborough - 18 November 2010
Noise and Vibration
Sheffield - 14 December 2010
Noise At Work
14-16 September 2010
Human Vibration
28-30 September 2010
Confined Spaces
19-21 October 2010
Managing Safely
25-28 October 2010