Home arrow Sound Meters arrow Sound Level Meters arrow GA116 - SONUS Pocket Sound Level Meters
Sound Level Meters

GA116 - SONUS Pocket Sound Level Meters

GA116 - SONUS Pocket Sound Level Meters
View Full-Size Image
£1,495.00  (Excluding VAT @ 17.5%)
:


The Castle SONUS is a new range of pocket meters designed for ease of use with the power the cover the work you need, from Noise at Work measurements to Environmental monitoring. The SONUS sound level meters are split into a range of meters to suit specific needs.

Different models are split into 3 variations – Basic, Integrating and Logging – with an option for a Class 1 or Class 2 meter. Each model is packed with features designed to help you get the measurements you need, from basic sound level meter to a full logging integrating sound meter.

The Basic SONUS model, the GA116B or GA216B, gives simultaneous sound pressure level (Lp), max (Lmax) and peak (Cpeak) measurements for initial spot-check assessments for Noise at Work Regulations and is designed for engineers and industrial safety officers and anyone with a need for simple and accurate sound measurements.

The Integrating SONUS, GA116I or GA216I, adds further functions and measurement parameters including Lep'd and Dose enabling the sound meter to also double as a dosemeter. The meter is ideal for Industrial Safety Officers and Safety Managers and can be used for Health and Safety at Work Act; Noise Regulations 1989. The GA116I gives all the required information for Noise at Work risk assessments.

Completing the SONUS range of sound level meters, the GA116L and GA216L are full data logging instruments, capable of measuring Ln and Le parameters while also adding an Exposure Calculation to the dosemeter measurements. With an additional real-time clock and USB connection to the dBdataPro analysis software the data logging meters can store data and give you the results in a format to suit.

 
GA116B
GA216B
GA116I
GA216I
GA116L
GA216L
Class
121212
Lp (SPL)
Leq
Lmax
Lmin
Pmax
Ln
Le (SEL)
% Dose
Projected Dose
Lep'd (Lex)
Dose/Hour
Pa2h
Exposure Calc
Number of Ranges
333333
Linearity Range
35-14035-4035-14035-14030-14030-140
Weighting
A, CA, CA, CA, CA, C, ZA, C, Z
Response Times
F, S, PF, S, PF, S, PF, S, PF, S, I, PF, S, I, P
Real-time Clock
Datalogging
Output
USBUSB
DC Power In
AC Output

Specifications

Applicable Standards:
I EC 61672-1:2002 Class 1 Group X
BS EN 61672-1:2003 Class 1 Group X
IEC 61252:1993
BS EN 61252-1997 + A1:2001

Microphone and Preamplifier:
Custom pre-amplifier design
Typical actuator to free-field correction factor (based on 500Hz=0) is shown below

20Hz: 01kHz: 0
25Hz: 01.25kHz: +0.2
31.5Hz: 01.6kHz: +0.4
40Hz: 02kHz: +0.5
50Hz: 02.5kHz: +1.0
63Hz: 03.15kHz: +1.2
80Hz: 04kHz: +1.5
500Hz: 05kHz: +2.0
630Hz: 06.3kHz: +2.5
800Hz: 08kHz: +3.8

Display:
Back-lit LCD panel (8x1 Characters)
Alpha-Numeric display for measured results

Level Range:
B and I Models:
Measuring Range: 35-140
Linear Operating Range (IEC61672-1): 65dB
3 Measurement Ranges (IEC61672-1): 35-100, 55-120 (Reference Range), 75-140

L Model:
Measuring Range: 30-140
Linear Operating Range (IEC61672-1): 70dB
3 Measurement Ranges (IEC61672-1): 30-100, 50-120 (Reference Range), 70-140
Peak: 3dB above top of selected range

Noise Floor:
Typical: 'A' Weighting 23 dB(A) rms,
'C' Weighting 24 dB(C) rms, 'Z Weighting 25 dB(Z) rms (L Only)

Frequency Weighting:
'A' and 'C' to IEC 61672-1:2002 and IEC 60651:1979+A1+A2
'Z' (L only) to IEC 61672-1:2002
Combinations of A, A&C simultaneous or A&Z simultaneous available for Leq, Lmax and Pmax

Frequency Range:
20 Hz - 8 kHz (including microphone)
1 Hz - 20 kHz (electrical characteristics)

Time Weighting:
Fast and Slow, Impulse (L only) in Accordance with IEC 61672-1-2002

DOSE Calculations:
Exchange rate: 3dB, 4dB or 5dB
Criterion Level: 75dB, 80dB, 85dB or 90dB
Threshold Level: -5dB, -10dB or OFF

Instrument Response:
Simultaneous Peak and RMS

Calibration:
Software controlled 91.0 to 120.0 dB (1kHz) in 0.1 dB steps

Memory:
2100 Data Intervals Maximum

Power Requirements:
Batteries: 1 x 6LR61 (size PP3), Life: >12 hours (alkaline batteries, continuous operation)

Size and Weight:
Dimensions: 60mm (width) x 35mm (depth excluding pocket clip) x 135mm (height without microphone) or 210mm (height with microphone)
Weight: 220gms (including battery)

Operating Temperature:
Operating Range: -10 to + 50șC

Humidity:
Effect: < 0.5dB from 25% to 90% RH

Vibration:
No effect on instrument

EMC:
Emissions: EC 61000-6-3, EN61326-1:2006, CISPR 22:1997
EN55022:1998, FCC Rules, Part 15 2003 Class B
Immunity: IEC 61000-6-2:2005, EN61326-1:2005
Levels ±4kV (Contact), ±8kV (Air)
Amp Mod: IEC 61000-6-2:2005, Level 10V/m



Click on the Logos for menus

Search

My Account






Lost Password?
No account yet? Register

Upcoming Seminars

Noise and Vibration
Scunthorpe - 21 April 2010

Audiometry
Leeds - 20 May 2010

Environmental Noise
Carlisle - 24 June 2010

Noise and Vibration
Southampton - 22 July 2010 2010

Upcoming Training

Noise At Work
23-25 March 2010

IOSH Managing Safely
26-29 April 2010

Air Sampling & COSHH
27-29 April 2010

Human Vibration (Hand-Arm & Whole Body)
15-17 June 2010