Blackline Indoor Location Beacon

06BCN-NA-001A

Be the first to review this product

Quick Overview

The Loner Beacon works hand in hand with all Loner devices to provide accurate positioning of Lone Workers inside buildings, where GPS signals are low or unreliable.

The clever technology of the Indoor Beacon enables you to map areas of your factory where Lone Workers may be present, including those areas on different floor levels.

With 5 year battery life and easy installation, these Beacons empower the Blackline Loner M6 system as the ultimate indoor Lone Worker system.

Price:

Talk to an expert about this product




Blackline ANThill Location Beacon
Blackline ANThill Location Beacon Blackline ANThill Location Beacon Blackline ANThill Location Beacon Blackline ANThill Location Beacon Blackline ANThill Location Beacon

Buy Online

£105.00

£105.00
Brand Blackline Safety
Available Outside the UK? No

Blackline Indoor Location Beacon

Working hand in hand with the Blackline Loner SMD and M6 devices, together these instruments create a powerful indoor Lone Worker Safety System.


Loner Indoor Location Beacons

These easy to install Indoor Location Beacons are fixed to surfaces in desired locations, and programmed via your own Loner Portal. Once the easy set up procedure has been completed, Loner devices can be accurately located when within a set distance of the beacons, even when GPS signals are not present. The benefit of combining the Loner Devices with the Indoor Location Beacons is the reduced time in acknowledging, locating and providing emergency assistance to workers in distress. Designed for industrial use, you'll only have to change the battery of the Indoor Location Beacon after 5 years.


Example of Use

A Maintenance Engineer slips and falls in a remote area of a manufacturing plant on a Sunday evening, when few staff are on site. Though the Engineer is wearing his Lone Worker Device, this particular area of the site has very low GPS signal; so despite a Man-Down alarm sounding in the Portal, and emergency Text and Email alerts are sent to the designated personnel, the location of the Engineer is not precisely displayed on the map provded. With the addition of Indoor Location Beacons placed in the low signal areas of the site, the Portal and message alerts would display which Beacon the Engineer was closest to - For Example, Boiler Room, Floor 2 - enabling the response team to arrive and provide the response required in as short a time as possible. Alert. Locate. Respond.

Video


Technical Specification

Size 63mm W x 107mm L x 26mm D (2.48” x 4.213” x 1.02”)
Weight 152g (5.4oz)
Safety Features Fall detection technology: Tri-axis accelerometers, tri-axis gyros, plus software processing
Emergency latch: Release latch to trigger emergency alert
Worker motion monitoring: Configurable time window (1 – 10 min)
Worker check-in (optional): Required check-in period (5 – 180 min)
Buttons and Indicator Lights Power button: Power on/off
Acknowledge button: Check-in / Silent emergency / Cancel pending alerts / Acknowledge alerts
Emergency latch: Send emergency alert
Red indicator light array plus vibration and buzzer: Safety alert triggered
Green indicator light: Blinking (powered), continuous (connected)
User Notification Indicators: Acoustic buzzer, LEDs, and vibration motor
Acoustic buzzer sound pressure level: ~90 dB @ 10 cm (~90 dB @ 3.94”)
Wireless Communication Radio: Quad-band GSM/GPRS (800, 900, 1800, 1900 MHz)
Antenna: Internal quad-band
Bidirectional communication with firmware upgrade over-the-air (FOTA)
Assisted GPS Radio: 20 channel high sensitivity, mobile assisted
Antenna: Internal Ultimate Sense 2® GPS antenna for weak GPS signal conditions
Accuracy: ~5 m (16 ft) outdoors, ~50 m (165 ft) indoors
Real-time location turnaround time: ~20 seconds
Alert Messages Fall detected / Emergency / No-motion / Missed check-in / Low battery / Power off / Silent emergency
Mobile Messaging Methods Email, Text Message (SMS)
Power Rechargeable Li-ion battery: 1500 mAh capacity
Charging connector: 4 pin sealed connection
Battery Life 20°C (68°F): 25 hours
-20°C (-4°F): 15 hours
Storage Temperature -30°C to 75°C (-22°F to 167°F)
Operating Temperature -30°C to 55°C (-22°F to 131°F)
Charging Temperature 0°C to 45°C (32°F to 113°F)
Ingress Protection Designed to meet IP65
Regulatory Compliance FCC, IC EU limits, Contains: FCCID W77BLlGSM1, IC 8255A - BLGSM1, CE 0682, Specific Absorption Rate, Certified Intrinsically Safe: Class I, Div. 1, Groups A, B, C and D, Class II, Div. 1, Groups E, F and G
Device Requirements Activated service plan, wireless communication coverage, GPS coverage for GPS locating
Warranty One year limited factory warranty. Wireless coverage and activated service plans.
Loner Portal Web Application Features Include: Alarm banner, event history, device location mapping, device management, alert & notification settings and more.
Wireless Coverage and Activated Service Plans Wireless coverage: Nearly 150 countries.

Downloads and Datasheets

Datasheet

ANThill Manual

ATEX Approval Certificate

ATEX Certificate

Infosheet & Beacon Setup

Infosheet

Loner M6 Beacon Setup Guide