Castle Safety/ Env. logging Sound System Class 1 (GA116L) Rental

Be the first to review this product

Free Delivery on this item! Book Online Below

The Sonus L model features parameters for measuring a wide range of applications. The Safety and Environmental Data Logging Sound System is designed for Noise at Work and Environmental measurements and features the Sonus Logging meter.

Alternatively, call 01723 584250 to arrange your booking

£199.00

* Required Fields

£199.00

1: Choose a Start Date


2: Choose Rental Duration

  • 1 Week
    £199.00 Selected
  • 2 Weeks
    £358.00 Selected
  • 3 Weeks
    £507.00 Selected
  • 4 Weeks
    £507.00 Selected
  • Short Term
    £119.00 Selected

For longer durations please contact us


3: Optional Extras

Add Damage Waiver +10% of total fee
Add Return Carriage Via Courier - £25

Quantity

Total Price
£
Castle Safety/ Env. logging Sound System Class 1 (GA116L) Rental

How do I book?

Booking is easy, choose your Rental Period, Start Date and any available accessories. After you click 'Add to Cart' and complete the checkout process we'll check your product is available and contact you to confirm your order.

The Damage Waiver is calculated at 10% of the cost of rental.

Return Carriage means we will arrange collection and return to us for £25.

Note that the Price shown here will reflect the instrument and Rental Period. Return Carriage and Damage Waiver costs will be added on the Cart and Checkout Pages.

Brand Castle Group
Application Environmental Noise, Field Calibration, Noise at Work
Features Data Logging
Class Class 1
Weightings A, C, Z
Measurement Parameters Leq, Lep’d (LEX)
Available Outside the UK? Yes

Compact and simple to use. The Safety and Environmental Sound Meter System features the SONUS GA116L logging noise meter which is capable of measuring all parameters required for Control of Noise at Work Regulations (including dose) and environmental parameters such as Ln. Data can be logged and downloaded using the dBdataPro noise analysis software. You can switch the removable microphone for the dosemeter cable microphone (available separately) and measure personal noise and dose levels. Environmental parameters include L10 and L90 measurements and a third selectable percentile level.

The GA116L brings simplicity and power to the world of Noise at Work and Environmental sound monitoring. It is a Class 1 instrument which is a full data logging, integrating sound and noise exposure meter and has been designed for both Noise at Work assessments and Environmental Sound Monitoring.

Then, the GA607 meets the demanding standards of a Class 1 calibrator. There are two calibration levels, 94dB and 104dB re re 20µPa both at 1kHz and it is supplied with the required barometer. It is for use with ½ “microphones. Using this meter, a sound level meter can be checked at two meter scale points and usually on two ranges. IEC 60942 states that for a calibrator to be used in the Class 1 category, it must be corrected for barometric pressure. There is a simple readout on the clear display and a correction table printed on the reverse which is a simple process.

IEC 60942 states that for a calibrator to be used in the Class 1 category, it must be corrected for barometric pressure. The Castle GA690 barometer is supplied with the GA607 Class 1/C calibrator for just this purpose. With a simple readout on the clear display and a correction table printed on the reverse, this is a simple process.

This kit can also be rented with the SONUS Weatherproof Case system for longer term environmental measurements outdoors.

Features
  • Measures Lp, Leq, Lmax, LE, Pa2h, Lep’d, DOSE,
  • Dose Per Hour, L10, L90, L(user)
  • User Modes: N@W, Environmental or ALL
  • Download data to a PC via a USB connection
  • Small and light weight
  • Single battery operation of approximately 12 hours

Technical Specification

Standards IEC61672-1-2002 (Sound Level Meters)
IEC61252-1993 (Personal Sound Exposure Meters)
Range Display Range Linear 30-100 29 101dB 30 – 100dB 40 – 103dB
50-120 59 – 121dB 50 – 120dB 60 – 123dB
70-140 69 – 141dB 70 – 140dB 80 – 143dB
Linear Operating Range 70dB
Detector Characteristics RMS and Peak
Frequency Weighting ‘A’, ‘C’ & ‘Z’ Weighted in Accordance with IEC 61672-1-2002
Combinations of ‘A’, ‘A’&’C’ simultaneous or ‘A’&’Z’ simultaneous available for Lp, Leq and Lmax
Time Weighting ‘Slow’, ’Fast’ and ‘Impulse’ in Accordance with IEC 61672-1-2002
Exchange Rate 3dB, 4dB or 5dB
Criterion Level 75dB, 80dB, 85dB or 90dB
Threshold Level 5dB, -10dB or OFF
Peak 3dB above top of selected range
Display Custom alphanumeric LCD, digit size 7mm x 5mm
Memory 2100 Data Intervals Maximum
Microphone / Preamp ACO 7146A pre-polarised ½” condenser microphone, 25mV / Pa
Calibration 91.0 to 120.0dB @ 1KHz
Batteries 1 x PP3 (9V)
Approximately 12 hours continuous use
Operating Temperature Range -10 to + 50ºC
Humidity Effect < 0.5dB from 25% to 90% RH
Vibration No Effect on Instrument
EMC Emissions: EC 61000-6-3, EN61326-1:2006, CISPR 22:1997
EN55022:1998, FCC Rules, Part 15 2003 Class B
Immunity: IEC 61000-6-2:2005, EN61326-1:2005
Levels ±4kV (Contact), ±8kV (Air)
Amp Mod: IEC 61000-6-2:2005, Level 10V/m
Construction ABS Plastic
Display Parameters Include: Lp (Sound Pressure Level)
Leq (Level equivalent) - dual measurement
Lep’d
LE
Lmax - dual measurement
‘C’ or ‘Z’ Weighted Peak
L10, L90 and Ln (user selectable)
Pa2Hrs (Dose % x 0.032)
Dose per Hour
Dose count 1% to 9999% with Variable exchange rate of
3dB,4dB or 5dB exchange rates
75dB, 80dB, 85dB or 90dB criterion va

Castle Sonus GA116L Class 1 Logging Sound Level Meter

GA116LStandards

IEC61672-1-2013 (Sound Level Meters) IEC61252-1993 (Personal Sound Exposure Meters) BS4142:2014 Methods for rating and assessing industrial and commercial sound

Selectable level ranges on the GA116L:

RANGEDISPLAY RANGELINEAR RANGEPEAK RANGE
30-10029 – 101dB30 – 100dB40 – 103dB
50-12059 – 121dB50 – 120dB60 – 123dB
70-14069 – 141dB70 – 140dB80 – 143dB
Linear Operating Range 70dB
Detector Characteristics RMS and Peak
Frequency Weighting ‘A’, ‘C’ & ‘Z’ Weighted in Accordance with IEC 61672-1-2002 Combinations of ‘A’, ‘A’&’C’ simultaneous or ‘A’&’Z’ simultaneous available for Leq, Lmax and Pmax
Time Weighting ‘Slow’, ’Fast’ and ‘Impulse’ in Accordance with IEC 61672-1-2002
Exchange Rate 3dB, 4dB or 5dB
Criterion Level 75dB, 80dB, 85dB or 90dB
Threshold Level -5dB, -10dB or OFF
Peak 3dB above top of selected range
Display Custom alphanumeric LCD, digit size 7mm x 5mm
Memory 2100 Data Intervals Maximum
Microphone/ Preamplifier ACO 7146A pre-polarised ½” condenser microphone, 25mV / Pa
Calibration 91.0 to 120.0dB @ 1KHz
Batteries 1 x PP3 (9V) Approximately 12 hours continuous use
Operating Temperature Operating Range: -10 to + 50ºC
Humidity Effect: < 0.5dB from 25% to 90% RH
Vibration No effect on instrument

Castle GA607 Dual Level Class 1 Sound Meter Calibrator

Applicable Standards IEC60942:2003 Sound Calibrators, Class 1/C
Output 94dB or 104dB relative to 20µPa
Nominal Sound Pressure level at 101.3kPa (760mm Hg) 23° & 50%RH
Tolerance ± 0.3dB
Harmonic Distortion < 3%
Temperature Range -10°C to 50°C
Batteries 2 x 3V CR2032 (coin cell)
Life: Approx. 70 Hours
Dimensions Cavity Diameter: 1/2" microphone standard
Length: 140mm
Diameter: 51mm
Weight: 230g

GA690 Barometer

Measuring Range 0 to 1300mbar (0 to 975mmHg)
Resolution 1mbar, 1mmHg
Accuracy ±0.25% FS hysteresis and linearity
Battery 9V Alkaline type 6LR61 (PP3)
Battery Life Greater than 2500 hours
Dimensions 106 x 67 x 30mm (LxWxH)
Weight 135g including battery

What's in the Box

The Castle Safety/ Env. logging Sound System Class 1 (GA116L) kit includes:

  • NK001A Class 1 Data-Logging Safety/Environmental Sound System Class 1 GA116L - Safety/Environmental Data-logging Sound Meter
  • GA607 Calibrator
  • Dual Level, Class 1 (includes GA690 Barometer)
  • KA010 Small Attache Kit Case
  • PC007 dBdataPRO Noise Analysis Software

Downloads and Datasheets

Castle Sonus GA116L Class 1 Logging Sound Level Meter

Datasheet

GA116L SONUS Sound Meters

Manual

Sonus Operating Manual GA116L and GA216L Quick Start Guide