This Occupational Noise Measurement System is designed to give Health and Safety Managers, or any other professional with responsibilities for managing noise in the workplace, everything they need to protect your workforce from over exposure to noise and to help you ensure your company is complying with The Control of Noise at Work Regulations 2005.
Boxed Weight (kg) | 1.5 |
---|---|
Brand | Castle Group |
Application | Noise at Work |
Features | Dose, Data Logging |
Class | Class 1 |
Weightings | A, C, Z |
Measurement Parameters | Lp, Leq, Lmax, Peak, %Dose Per Hour, Dose, HSE Exposure Points, Lep’d (LEX), Points Per Hour, LAF |
Available Outside the UK? | Yes |
The Noise Measurement System is designed to give Health and Safety Managers, or any other professional with responsibilities for managing noise in the workplace, everything they need to protect your workforce from over exposure to noise and to help you ensure your company is complying with The Control of Noise at Work Regulations 2005. With it's simple measurement set up and intuitive interface, the SONIK-S makes conducting occupational noise surveys simple and straightforward.
This system includes a Class 1 Sound Meter with protective rubber casing, Class 1 Acoustic Calibrator, PC Noise Analysis Software, Cloud Based Noise Analysis Software and a Protective Carry Case.
This SONIK-S Noise Measurement System is ideal for a range of Occupational Noise applications:
Instrument Standards: IEC 61672-1: 2002 Class 1 Group X IEC 61672-1: 2002 Class 2 Group X |
Languages: English UK, English US, Chinese, French, German, Italian, Portuguese Brazilian, Russian, Spanish, Dutch, Greek |
||||||||||||
Level Ranges:
|
Quick Setup Modes (SONIK-SE Only): Noise at Work, Environmental, All Parameters |
||||||||||||
Frequency Range 1 Hz - 20 kHz (electrical characteristics) Class 1: 10 Hz - 20 kHz (including microphone) Class 2: 20Hz - 8kHz (including microphone) |
Microphone: Class 1: ½” Pre-Polarized - Free Field (IEC) Pressure (ANSI) Sensititvity (25mV/Pa)
Class 2: ½” Pre-Polarized - Free Field (IEC) Pressure (ANSI) Sensititvity (25mV/Pa) |
||||||||||||
Measurement Channels: Two |
Microphone Preamplifier: Low Noise, Removable Preamplifier |
||||||||||||
Parameters: SONIK-S: Lp, Leq, Lmax, Lpeak, Exposure Pa2h, Lep'd, %Dose, %Dose Per Hour, Points, Points Per Hour, Under Range, Overload SONIK-SE: As SONIK-S, plus LE, L10, L90 and either L1, L5, L50, L95, L99 |
Noise Floor (Typical): ‘A’ Weighting < 16.0dB ‘C’ Weighting < 17.2dB ‘Z’ Weighting < 18.9dB |
||||||||||||
Linear Operating range: 75 dB |
Display: 2.4” Full Colour TFT 240x320 pixels |
||||||||||||
Frequency Weighting: ‘A’, ‘C’ and ‘Z’ Combinations of ‘A’, ‘A’&’C’ simultaneous or ‘A’&’Z’ simultaneous available for Lp, Leq and Lmax
|
Batteries: 4 x AA (1. 5V) - Typically 20 hours continuous use (screen settings dependent) |
||||||||||||
Time Weighting: ‘Slow’, ’Fast’ and ‘Impulse’ |
External Power:Micro USB type B, 0.5A |
||||||||||||
Percentiles (SONIK-SE only): L10, L90 and either L1, L5, L50, L95, L99 |
Connections: Micro USB type B |
||||||||||||
Exchange rate: 3dB, 4dB or 5dB |
Environmental: Temperature Operating Range: -10 to + 50ºC Humidity: Up to 90% RH Non-Condensing |
||||||||||||
Criterion Level: 75dB, 80dB, 85dB or 90dB |
Case: High Impact ABS plastic with membrane keypad |
||||||||||||
Threshold Level: -5dB, -10dB or OFF |
Size and Weight Dimensions: Including Pre-Amplifier: 260mm (H) x 67mm (W) x 26mm (D) Excluding Pre-Amplifier: 184mm (H) x 67mm (W) x 26mm (D) |
||||||||||||
Memory: 4MB – Up to 4000 Data Intervals Maximum in one or multiple recordings |
Weight: 207g (Without Batteries |
GA142S - SONIK Safety Data-logging Sound Meter Class 1
GA611 - Calibrator, Class 1
PC007 - dBdataPRO Noise Analysis Software & Cable
CCPROFREE - FREE Account for Castle Cloud - 1 User, 1 Instrument
KA017 - Protective System Carry Case
dB001 - dBAir Rubber Boot Orange
GA242S - SONIK Safety Data-logging Sound Meter Class 2
GA612 - Calibrator, Class 2
PC007 - dBdataPRO Noise Analysis Software & Cable
CCPROFREE - FREE Account for Castle Cloud - 1 User, 1 Instrument
KA017 - Protective System Carry Case
dB001 - dBAir Rubber Boot Orange
You can analyse your data using either Cloud or PC Based software that's free and simple to use.
The SONIK sound level meters can be used with TheCastleCloud.com, a secure Cloud based noise analysis software that can be accessed from any device with a browser and an internet connection. Your data is secure and easily manageable, and has full noise analysis features.
Having instant access to all of your data on one screen means better decision making and streamlined operation. With all the data on-screen, dBdata allows you to manage the data files, copy out the data you want and print reports directly to hard copy.
For increased functionality, there is the option to upgrade to the full dBdataPRO software, which gives the benefit of greater data-manipulation, graphical views and analysis for hearing protection, dose calculations and NR curves.
Sound Meters by Application |
SONIK-S |
SONIK-E |
SONIK-SE |
Occupational Noise Assessments for The Control of Noise at Work Regulations 2005 |
x |
|
x |
Hearing Protection Selection Assessments on Instrument |
|
|
|
Hearing Protection Selection Assessments (via dBData software) |
x |
|
x |
Simple Noise Level Testing |
x |
x |
x |
Fire Alarm Volume Testing |
x |
|
x |
Machinery Servicing and Maintenance |
x |
|
x |
Measurements for the Environmental Noise Regulations 2006 (EU Environmental Noise Directive) |
|
x |
x |
Traffic Noise |
|
x |
|
Measurements in accordance with BS 5228 |
|
x |
x |
Neighbour Noise Nuisance |
|
x |
x |
Community Noise Assessments |
|
x |
x |
Measurements in accordance with BS 4142:2014 |
|
x |
x |
Noise Nuisance from Industrial or Commercial Premises |
|
x |
x |
Noise Measurements for Planning |
|
x |
x |
For applications with noise levels down to 20dB |
|
x |
|
Sound Power |
x |
|
x |